Opvarmet boligareal (m²)75% dækning – boliger efter 1985
(Kedelydelse kW)
Boliger bygget efter 1985
(Kedelydelse kW)
Boliger bygget før 1920
(Kedelydelse kW)
10061016
200131631
300172445
400233060
500283775
600334590

Kilde: Teknologisk Institut, Installationsvejledning for biobrændselskedler, oktober 2000

Find boiler size based on the home’s floor area and age

To select the right boiler size, you can either base it on your annual oil or gas consumption or – if the consumption is unknown – on the size and age of the home

The table helps you find the boiler output that matches both modern, well-insulated homes and older houses with greater heat loss.
We have included an additional heat demand of 2 kW for domestic hot water, so the result is more realistic.

If you have an oil boiler in the system, it can be used as a backup during peak load, which allows the boiler to be sized down to around 75% of the total heat demand.